Products

SRPT-750 Single Phase Relay Tester

1.Designed for rugged field use

2.0 to 100 Amp output current (overload 150A)

3.Suitable for testing many different types of relays such as power, voltage and current

4.Easy to operate

description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Overview

Overview

Compact design and light weight makes SRPT-750 extremely portable, mostly used for almost all types of single phase relays test. 

Parameters

Ammeter Voltmeter
Measurement method AC true RMS Measurement method AC true RMS
DC mean value DC mean value
Range Internal: 0.000~150.0A; Range 0.0~600.0V (AC or DC)
External: 0.000~6.000A (AC or DC) Accuracy 0.50%
Accuracy 0.50%

Timer General
Measurement method 0~999.999s, automatically reset after
full scale
Environmental Conditions Operating temperature: -10~50
Range 1mS Humidity: 90%
Accuracy ±1mS Mains voltage 200~250VAC, 50/60Hz
Power consumption 1000W
Net Size 420mm×350mm×200mm
Net Weight 18kg(without measuring cables)

Current outputs-AC Voltage outputs-AC/ DC
Range No-load voltage
(min)
Full-load voltage
(min)
Full-load current
(max)
Range No-load voltage
(min)
Full-load voltage
(min)
Full-load current
(max)
0~10A 90 10 10A 0~250V(AC) 250 240 3A
0~40A 25 22 40A 0~300V(DC) 320 250 4A
0~100A 10 8 100A

Auxiliary DC output Auxiliary AC output
Range Voltage Max current Range Voltage Max current
0~110V DC 120V DC 0.5A 0~250V(AC) 120V AC 0.5A
110~220V DC 220V DC 0.5A 0~300V(DC) 5V AC 8A
Parameters

Parameters

Ammeter Voltmeter
Measurement method AC true RMS Measurement method AC true RMS
DC mean value DC mean value
Range Internal: 0.000~150.0A; Range 0.0~600.0V (AC or DC)
External: 0.000~6.000A (AC or DC) Accuracy 0.50%
Accuracy 0.50%

Timer General
Measurement method 0~999.999s, automatically reset after
full scale
Environmental Conditions Operating temperature: -10~50
Range 1mS Humidity: 90%
Accuracy ±1mS Mains voltage 200~250VAC, 50/60Hz
Power consumption 1000W
Net Size 420mm×350mm×200mm
Net Weight 18kg(without measuring cables)

Current outputs-AC Voltage outputs-AC/ DC
Range No-load voltage
(min)
Full-load voltage
(min)
Full-load current
(max)
Range No-load voltage
(min)
Full-load voltage
(min)
Full-load current
(max)
0~10A 90 10 10A 0~250V(AC) 250 240 3A
0~40A 25 22 40A 0~300V(DC) 320 250 4A
0~100A 10 8 100A

Auxiliary DC output Auxiliary AC output
Range Voltage Max current Range Voltage Max current
0~110V DC 120V DC 0.5A 0~250V(AC) 120V AC 0.5A
110~220V DC 220V DC 0.5A 0~300V(DC) 5V AC 8A